Self-Diagnosis Code Table
|
|
Symptom/State |
|
01 |
Tape slacking is detected in the threading or unthreading operation. |
|
02 |
Tape slacking or tape breaking is detected in the SEARCH, FF, or REW mode. |
|
03 |
Tape slacking, tape breaking, or supply or take-up reel locking is detected in
the REC or PLAY mode. |
|
04 |
A malfunctional tape transport speed is detected in the FF or REW mode. |
|
05 |
The malfunctional operation of the supply or take-up reel is detected during
cassette insertion. |
|
06 |
Excessive tape tension is detected in the REC or PLAY mode. |
|
07 |
Malfunction of capstan motor is detected. |
|
08 |
Malfunction of drum motor is detected. |
|
09 |
Malfunction of threading or unthreading operation is detected. |
|
0A
|
It is detected that the tape top processing is not completed in the threading
mode. |
|
10 |
Dew condensation is detected. |
|
11 |
The tape top and tape end are detected simultaneously. |
|
12 |
Malfunction of tape top sensor is detected. |
|
13 |
Malfunction of tape end sensor is detected. |
|
14 |
Malfunction of cooling fan motor is detected. |
|
20 |
Malfunction of cassette compartment-up or down operation is detected. |
|
21 |
Malfunction of movement of the reel table corresponding to the cassette size is
detected. |
|
22 |
The L-cassette and S-cassette positions of the reel table are detected
simultaneously. |
|
23 |
The thread end and unthread end states of the threading ring are detected
simultaneously. |
|
92 |
When the communication between SYS CPU (IC1106 on the SS-101 board) and the
device listed below is in abnormal state. CP MPU IC706 on CP-396 board SYS2 MPU
IC102, LCD rendering IC201 or IC301, or DPRAM IC405 on SY-340 board EEPROM IC115
or IC116 on FP-153 board. |
|
93 |
Abnormality in the interface between SV CPU (on SS-101 board) and DR MPU (on
DR-508 board) is detected. |
|
95 |
Abnormality operation of an NV-RAM on FP-153 board is detected. |
|
96 |
The abnormal operation of an NV-RAM (on FP-153 board) for the system control
system is detected. |
|
97 |
The abnormal operation of an NV-RAM (on DR-508 board) for the servo system is
detected. |
|
98 |
The abnormal operation of the NV-RAM for the RF system (on the EQ-104 board) or
NVRAM for video processing system (VPR-98 board) is detected. |
|
99 |
Abnormality in the interface between SYS CPU (on SS-101 board) and SERVO CPU (on
ERROR 2 SS-101 board) or MPU (on APR-80, EQ-104, HPR-21, PD-117, SY-340, TSI-58,
or VPR-98 board) is detected. |
|
E0
|
An error was detected during initialization of network interface (VN-13 board). |
|
E1
|
A hardware error was detected during data communication via the network. |
|
E2
|
An error was detected in the file system data stored in the Tele-File label. |
|
E3
|
A software processing error was detected during data communication via the
network. |
|
E4
|
Communication timeout between SYS CPU (SS-89 board) and VN CPU (VN-13 board) or
a hardware error was detected. |
|
E5
|
FPGA (EPR-1 board) program version does not comply with network operation. |