Self-Diagnosis Code Table
|
|
Symptom/State
|
|
02-020
|
Optical block assembly (OP0) (referred to as OP hereafter) is recording at maximum
laser output. Perform the pickup lens cleaning.Perform the pickup lens cleaning.
|
|
02-F2E
|
OP laser is determined to be deteriorated in the laser deterioration assessment
for OP (OP0).
|
|
02-F37
|
No movement is detected in the ND filter initial operation check of OP (OP0).
|
|
02-X25
|
OP (OP0) laser output error is detected.
|
|
02-X26
|
OP (OP0) laser output coefficient cannot be adjusted.
|
|
02-X27
|
OP (OP0) laser current is abnormal (zero or excessive).
|
|
02-X28
|
OP laser output is stopped judging that no cartridge is inserted.
|
|
02-X37
|
OP (OP0) ND filter setting cannot be changed.
|
|
03-060
|
OP (OP0) tracking servo is frequently down.
|
|
03-X54
|
No signal from disc required for OP (OP0) focus servo can be detected.
|
|
03-X57
|
No control current is detected in OP (OP0) focus servo.
|
|
03-X58
|
Excessive control current is detected in OP(OP0) focus servo.
|
|
03-X67
|
No control current is detected in OP (OP0) tracking servo.
|
|
03-X68
|
Excessive control current is detected in OP (OP0) tracking servo.
|
|
04-X7C
|
OP (OP0) cannot move to disc’s innermost circumference.
|
|
04-X7D
|
OP (OP0) cannot move to disc’s outermost circumference.
|
|
06-049
|
OP (OP0) SA actuator cannot move to the target position.
|
|
06-E41
|
OP (OP0) SA actuator home position cannot be detected during startup adjustment.
|
|
06-F41
|
OP (OP0) SA actuator home position cannot be detected during power-on initialization.
|
|
08-091
|
Spindle motor does not rotate after the predetermined time has passed (or no FG
signal is detected).
|
|
08-095
|
Spindle motor cannot be stopped (or abnormal FG signal is detected).
|
|
08-292
|
Spindle motor rotation is detected during vertical move of loading.
|
|
08-992
|
Spindle motor rotation is detected during vertical move of unloading.
|
|
20-108
|
An abnormal current of the loading motor is detected.
|
|
20-111
|
Horizontal move of loading did not end within the predetermined time.
|
|
20-117
|
Displacement of cartridge is detected in the loader during horizontal move of loading.
|
|
20-118
|
An abnormal current of the loading motor is detected during horizontal move of loading.
|
|
20-211
|
Vertical move of loading did not end within the predetermined time.
|
|
20-213
|
Cartridge cannot be detected after loading.
|
|
20-217
|
Displacement of cartridge is detected in the loader during vertical move of loading.
|
|
20-218
|
An abnormal current of the loading motor is detected during vertical move of loading.
|
|
20-811
|
Ejection operation did not end within the predetermined time.
|
|
20-818
|
An abnormal current of the loading motor is detected during the ejection operation.
|
|
20-911
|
Unchucking operation did not end within the predetermined time.
|
|
20-918
|
An abnormal current of the loading motor is detected during the unchecking operation.
|
|
34-500
|
Loader position sensor (SE-852 board) is detects abnormal code.
|
|
34-509
|
Sensor hole (SE-850/851 board) is detects abnormal code.
|
|
35-500
|
(Not displayed)X O Abnormality of acceleration sensor is detected.
|
|
37-500
|
High TEMP! X O Optical block assembly (OP0) temperature sensor detects abnormal
status.
|
|
3C-500
|
HUMID! X O Dew condensation is detected.
|
|
50-010
|
(Not displayed)X O BCA area data cannot be read.
|
|
50-011
|
(Not displayed)X O BCA area data is invalid.
|
|
51-020
|
DI read err X O PIC area data cannot be read.
|
|
51-021
|
DI read err X O PIC area data is invalid.
|
|
52-X0B
|
Read err X O Address cannot be read from disc in optical block assembly (OP0).
|
|
60-E00
|
(Not displayed)X O Optical block assembly (OP0) cannot seek to target position during
startup.
|
|
6F-E00
|
DRV ADJ err X O Optical block assembly (OP0) startup adjustment cannot be completed.
|
|
91-125
|
System control CPU detects interruption in communication with key control CPU (KY:
U1/KY-624 board).
|
|
91-130
|
System control CPU detects flash memory (IC2905, IC2906/HPR-23 board) error.
|
|
91-13B
|
System control CPU detects an error in hours meter area (EEPROM:IC2701/HPR-23 board).
|
|
91-13C
|
System control CPU detects an error in adjustment data area (EEPROM:IC2701/HPR-23
board).
|
|
91-13D
|
System control CPU detects an error in hours meter area (EEPROM:IC2907/HPR-23 board).
|
|
91-155
|
Communication between system control CPU and optical drive (DR-601 board) is interrupted.
|
|
91-165
|
System control CPU detects interruption in communication with camera control CPU
(IC209/AT-177 board) (System control CPU detects).
|
|
91-185
|
System control CPU detects interruption in communication with IC for driving color
LCD (IC1/PD-118 board) (System control CPU detects).
|
|
91-1C1
|
System control CPU detects software option’s installation key error.
|
|
91-215
|
Key control CPU (KY: U1/KY-624 board) detects interruption in communication with
system control CPU.
|
|
91-239
|
Key control CPU (FP: IC921/FP-157 board) detects EEPROM (IC913/FP- 157 board) error.
|
|
91-23E
|
Key control CPU (FP: IC921/FP-157 board) detects color LCD EEPROM (IC3/PD-118 board)
error.
|
|
91-275
|
Key control CPU (FP: IC921/FP-157 board) detects I2C I/O (IC202/CNB- 25 board) error.
|
|
91-285
|
Key control CPU (FP: IC921/FP-157 board) detects interruption in communication with
color LCD EEPROM (IC1/PD-118 board) error (Key control detects).
|
|
91-2B5
|
Key control CPU (FP: IC921/FP-157 board) detects Real time Clock (IC908/FP-157 board)
error.
|
|
91-430
|
CPU (NET-4 board) detects flash memory (IC907,IC908/NET-4 board) error.
|
|
91-551
|
Optical drive’s system control CPU (DRV: IC600/DR-601 board) detects firmware error.
Perform the firmware update.
|
|
91-595
|
Optical drive’s system control CPU (DRV: IC600/DR-601 board) detects interruption
in communication with SV DSP (IC400/DR-601 board) on the OP0 side.
|
|
91-596
|
Optical drive’s system control CPU (DRV: IC600/DR-601 board) detects no reply from
SV DSP (DRV: IC400/DR-601 board) on the OP0 side during communication with SV DSP.
|
|
92-101
|
System control CPU detects REF FOE error.
|
|
92-102
|
System control CPU detects REC FOE error.
|
|
95-101
|
Communication error between system control CPU and PCI bridge (IC801/HPR-23 board)
is detected.
|
|
95-102
|
Communication error between system control CPU and i.LINK (IC1201/HPR-23 board)
is detected.
|
|
95-103
|
Communication error between system control CPU and composite decoder (IC100/IV-59
board) is detected.
|
|
95-104
|
Communication error between system control CPU and MPEG IMX encoder (IC1600/DVP-45
board) is detected.
|
|
95-107
|
System control CPU detects an error in the MPEG encode device (TORINO: IC201, 401,
601 / ENC-107 board).
|
|
95-108
|
MMPEG encode device (TORINO: IC201 / ENC-107 board) has an error.
|
|
95-109
|
System control CPU detects an error in the MPEG decode device (TORINO: IC801, 1001
/ ENC-107 board).
|
|
95-10A
|
MMPEG decode device (TORINO: IC201 / HPR-23 board) has an error.
|
|
95-10C
|
System control CPU detects signal processing device LVIS (IC501/HPR-23 board) error.
|
|
95-10F
|
SSystem control CPU detects PROXY decoder (IC501/HPR-23 board) error.
|
|
95-110
|
System control CPU detects PROXY encoder (IC501/HPR-23 board) error.
|
|
95-111
|
SSystem control CPU detects PB DSP0 (IC1801/HPR-23 board) error.
|
|
95-113
|
System control CPU detects REC DSP0 (IC1701/HPR-23 board) error.
|
|
95-116
|
SSystem control CPU detects LRZ DSP0 (IC2001/HPR-23 board) error.
|
|
95-503
|
Optical drive’s BDC (IC300/DR-601 board) error is detected during initial check.
|
|
95-507
|
AAdjustment data cannot be read from EEPROM in OP (OP0).
|
|
95-508
|
Hours meter data cannot be read from EEPROM in OP (OP0).
|
|
95-509
|
AAdjustment data cannot be read from optical drive’s EEPROM (IC4/SE-850 board).
|
|
95-50A
|
Hours meter data cannot be read from optical drive’s EEPROM (IC4/SE-850 board).
|
|
95-50C
|
OOptical drive’s SYS PE (IC700/DR-601 board) configuration error is detected.
|
|
95-50F
|
Cannot access SDRAM (IC300/DR-601 board) for Optical driver’s BDC (IC300/DR-606
board).
|
|
95-513
|
OOptical drive’s (OP0) BDC (IC300/DR-601 board) cannot set the SDRAM mode.
|
|
95-51C
|
Optical drive’s (OP0) BDC (IC300/DR-601 board) cannot reset free-run by SYS PE (IC700/DR-606
board).
|
|
95-52C
|
Auto setting by SYS PE (IC700/DR-601 board) is disabled with power control of optical
drive’s (OP0) BDC (IC300/DR-601 board).
|