Self-Diagnosis Code Table
|
|
Symptom/State |
Corrections |
|
C:04:00 |
None-standard battery used |
Use info LITHIUM battery
|
|
C:21:00 |
Condensations |
Remove the cassette and inset is back after an hour |
|
C:22:00 |
Video Head is dirty |
Clean with the optional cleaning cassette |
|
C:31:10 |
LOAD direction. Loading does not complete within specified time |
Load the tape again, and perform operations from the beginning |
|
C:31:11 |
UNLOAD direction. Loading does not complete within specified time |
Load the tape again, and perform operations from the beginning |
|
C:31:20 |
T reel side tape slacking when unloading |
Load the tape again, and perform operations from the beginning |
|
C:31:21 |
Winding S reel fault when counting the rest of tape |
Load the tape again, and perform operations from the beginning |
|
C:31:22 |
T reel fault |
Load the tape again, and perform operations from the beginning |
|
C:31:23 |
T reel fault |
Load the tape again, and perform operations from the beginning |
|
C:31:30 |
FG fault when starting capstan |
Load the tape again, and perform operations from the beginning |
|
C:31:31 |
FG fault during normal capstan operations. |
Load the tape again, and perform operations from the beginning |
|
C:31:40 |
FG fault when starting drum |
Load the tape again, and perform operations from the beginning |
|
C:31:41 |
PG fault when starting drum |
Load the tape again, and perform operations from the beginning |
|
C:31:42 |
FG fault during normal drum operations |
Load the tape again, and perform operations from the beginning |
|
C:31:43 |
PG fault during normal drum operations. |
Load the tape again, and perform operations from the beginning |
|
C:31:44 |
Phase fault during normal drum operations. |
Load the tape again, and perform operations from the beginning |
|
C:32:10 |
LOAD direction loading motor time-out |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:11 |
UNLOAD direction loading motor time-out |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:20 |
T reel side tape slacking when unloading |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:21 |
Winding S reel fault when counting the rest of tape |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:22 |
T reel fault |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:23 |
S reel fault |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:30 |
FG fault when starting capstan |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:31 |
FG fault during normal capstan operations. |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:40 |
FG fault when starting drum |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:41 |
PG fault when starting drum. |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:42 |
FG fault during normal drum operations |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:43 |
FG fault during normal drum operations |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:44 |
Phase fault during normal drum operations |
Remove the battery or power cable, connect, and perform operations from the
beginning |
|
C:32:60 |
Difficult to adjust focus (Cannot initialize focus.) |
Remove the battery or power cable, connect, and perform operations from the
beginning. If it does not recover, inspect the focus MR sensor of lens block
(Pin wl, ea of CN5802 on the YY-003 board). If not faulty, inspect the focus
motor drive circuit (IC6004 on the YY-003 board). |
|
E:61:10 |
Zoom operations fault (cannot initialize zoom lens) |
Contact service engineer at 1-800-255-5045 |
|
E:61:11 |
Focus lens initializing failure and zoom lens initializing failure occur
simultaneously. |
Contact service engineer at 1-800-255-5045 |
|
E:62:00 |
Steady shot function does not work well. (with pitch angular velocity sensor
output stopped.) |
Contact service engineer at 1-800-255-5045 |
|
E:62:01 |
Steady shot function does not work well. (with yaw angular velocity sensor
output stopped.) |
Contact service engineer at 1-800-255-5045 |
|
E:62:02 |
Abnormality of IC for steadyshot. |
Contact service engineer at 1-800-255-5045 |
|
E:62:03 |
IC for steadyshot and micro controller
communication abnormality among. |
Contact service engineer at 1-800-255-5045 |
|
E:62:10 |
Shift lens initializing failure |
Contact service engineer at 1-800-255-5045 |
|
E:62:11 |
Shift lens overheating (Pitch) |
Contact service engineer at 1-800-255-5045 |
|
E:62:12 |
Shift lens overheating (Yaw) |
Contact service engineer at 1-800-255-5045 |