maintenance schedule for my
AG DV2500P deck
?
AG DV2500P
  Maintenance is performed periodically in order to preserve all functions in good working condition, Video equipment with mounted mechanism use wear parts, wear and deterioration will cause miscelouse malfunctions. Dust, dirt and salt can also impair stable operation. It is important not to just perform repair at the time of
breakedown, but also to perform suitable maintenance at regular intervals.
Self-Doagnosis Code Table
|
|
Symptom/State
|
|
0201 |
DEW detected |
|
3200 |
Does not load |
|
3300 |
Does not unload |
|
4100 |
Does not eject |
|
5605 |
Tape abnormality during intake |
|
5606 |
Tape tear during unloading |
|
5607 |
Tape tear during loading |
|
5608 |
Tape tear on the loading side |
|
5609 |
Tape tear during slack takeup |
|
5702 |
End sensor malfunction |
|
5802 |
Begin sensor malfunction |
|
7001 |
Drum motor does not rotate |
|
7101 |
Capstan motor does not rotate |
|
7202 |
Supply reel does not rotate |
|
7203 |
Supply side tape slack |
|
7302 |
Take up reel does not rotate |
|
7303 |
Take up side tape slack |
|
7305 |
Tape slack during unloading |
|
7401 |
Reel motor does not rotate |